AVL Skills Center
AVL Tech-Info AVL Tech-Info
Contact Contact
 
Languages Languages
English
German


AVL Temperature Sensors

Accurate measurements at temperatures up to 300°C are carried out using PT 100 sensors and four-wire technology. K-type thermocouples are used for temperatures up to 1000°C. The 3 mm casing diameter makes installation easy. A high response rate is achieved due to the low sensor mass. Continuous shielding from the casing to the plug provides high resistance to interference. The special anti-buckle design ensures mechanical stability. 8-pin DIN plugs are used to connect the temperature sensors straight to the F-FEM-AI*.


Data Sheet View File Download File




View Print View Print
Send to Friend Send to Friend
Back to Top Back to Top
Help |  Legal Information |  Impressum |  © AVL 2008