Technical specifications of control and analyzer unit:Dimensions: 660 x 900 x 2000 mm Weight: 290 kg Ambient conditions: 5°C to +35°C Power requirements: 3 x 400 VAC, ±10%, 50 Hz
The system is equipped with the following analyzer modules: FID 4000 hcFlame Ionization Detector, cold Measuring ranges (up to 4): 0 - 10 ppm / 0 - 5000 ppm Hardware supports a single span gas (up to 4 optionally available)
CLD 4000 hcVacuum Chemiluminiscence Detector, cold Measuring ranges (up to 4): 0 - 10 ppm / 0 - 1000 ppm Hardware supports a single span gas (up to 4 optionally available)
IRD 4000 NDIRCO2 Measuring ranges (up to 4): 0 – 1 %/ 0 – 20% Hardware supports a single span gas (up to 4 optionally available)
COlow Measuring ranges (up to 4): 0 - 50 ppm / 0 - 5000 ppm Hardware supports a single span gas (up to 4 optionally available)
Technical specifications Constant Volume Sampling UnitDimensions: 660 x 900 x 1115 mm Weight: 110 kg Ambient conditions: 5°C to +35°C Bags: 1 ambient bag, 1 sample bag standard Single Venturi: Maximum flow rate: 6 m³/min Integrated Blower: max. 590 m³/h, 5.4 kW, 50 Hz Power: 3 x 400 VAC ± 10 %, 50 Hz
Technical specifications AutomationIn order to avoid redundancies and to offer a competitive package the automation software and the controller software run on the same hardware – only a single PC is necessary.
It consists of the following hardware and software components:
Desktop PC with- 15” TFT display for test run administration and driver’s aid
- Win XP operating system and Office XP, pre-installed
Automation Package- Test automation for ECE R40, ECE R47, 87/24/EG, GB 14622-2002; GB 18176-2002
- Evaluation package for bag analysis including test protocol
- Driver’s aid software application
- Analog interface to chassis dynamometer
Technical specifications Exhaust Gas TesterStand alone gas analyzer for online measurement at idle speed.
Measuring range: CO2: 0...20%, CO: 0...10% |