AVL BOBCAT - Testing Solutions for Large Engines

The COMPACT solution for engine test automation & control
AVL BOBCAT
AVL BOBCAT™ is an affordable and integrated engine testing automation system from AVL's COMPACT product line for both existing and new test cell layouts.
AVL Approach
With AVL BOBCAT™ the user is entering an "open highway" to a future of expanding test solutions and outstanding AVL services which will fit both current and future needs.
Benefits at a Glance
- Intuitive modular structure for creating test cell, engine and test run definition and procedure configuration
- User-friendly experience driven by aesthetic display pages and graphical drag-and-drop test set-up
- Quick operation that allows test runs to be defined and reused easier and initiated faster
Functions
- Digital Dynamometer & Engine Controller provides excellent torque and speed control
- Proven interfaces to hydraulic, eddy current and AC dynamometers are available
- Interfaces to most common measuring devices for engine testing can be easily established
Technical Data
Operating system | Windows XP or Windows 7 |
Realtime operating system | INtime |
Modes of operation | Manual and automatic |
Channels types | Analog IO, digital IO, temperature, formula, filters, PID, limits, custom and dependent |
Channel frequencies | 1, 10, and 100 Hz (1kHz for F-FEM CON channels) |
Calibration history | History maintained, trace maintained |
Limit monitoring types | Testcell limit (monitored either in testcell load or engine loaded states), engine limit and group (monitored when engine has started) |
Limit monitoring reactions | Low and high warnings and alarms; SoftStop, HardStop, Message, Idle and Exception on alarms. |
Filters types | Cut-off frequency, Integrator, Value changed/not changed, moving average, invalid value and minimum/maximum/range |
Maximum number of channels | 4750 |
Maximum number of PID channels | 10 |
Maximum number of testcell limit Channels | 128 |
Maximum number of active recorders | 3 concurrently activated recorders and 1 blackbox recorder |
Recording frequencies | 1, 10, 100 Hz (1kHz for F-FEM CON channels) |
Maximum number of CAN ports | 8 (4 for each CAN card) |
Test result data | Export data as CSV and ATF, or upload to Santorin database |
EMCON Control modes | Speed/Position, Torque/Position, Speed/Torque, Torque/Speed, Dyno/Speed, Speed/Aux, Torque/Aux, Torque function of Speed/Position |
Supported Dynamometers | Eddy current Hydraulic (water brake) Motoring dyno (AC or DC) Bi-directional motor controller, i.e. Spintron. Motoring dynos are supported on a case by case base. |
Peripheral Devices | AVL DiGas 1000, AVL 733S, AVL 735, AVL 753C, AVL 415, AVL 439, AVL 442, AVL 483, PEUS CFO, HMT 333, PTU 300, CVS, Simplex_LB, FMU3G, Agilent, EBH, Emissions Benches, CAS/ACAP, SPC, CAN, ASAP3, CUTY, IndiCom |