Product

AVL iCAL Emission Calibration Devices

Accuracy through innovation

The iCAL product line includes everything you need to accurately calibrate emission measurement devices according to the legal obligations of global markets. 

iCAL SL

AVL iCAL GDU SlimLine (SL) Gas Dividers are used to verify the linearity of analyzers used for emission certification and R&D testing. The integrated converter tester (iCAL GDU/GNU SL) determines the efficiency of NOX converters used in chemiluminescence detector (CLD) analyzers. The iCAL CFO SL propane injection tester is ideal for testing for compliance with regulatory demands for frequent Critical Flow Orifice (CFO) testing. The AVL iCAL LFE (Laminar Flow Element) includes accurate sensors for temperature and pressure and is used to calibrate critical flow venturis and mass flow controllers (MFCs). The iCAL HBU Heated Bubbler is applied for quality checks such as a sample dryer and a CLD quench verification.

The accuracy of exhaust measurement systems is highly dependent on the quality and precision of the calibration devices used. In order to guarantee high quality results, minimize operating errors and reduce operating times, we have created the AVL iCAL product line of emission calibration devices, including slim solutions for crowded test fields, such as the AVL iCAL SL (SlimLine) Gas Dividers and CFO Testers. 
AVL’s ISO 17025 accredited calibration laboratory and numerous installations at regulatory bodies demonstrate the highest levels of accuracy required to determine compliance with the complex regulatory requirements.

iCAL calibration emission device

Combined Functionality for More Space

To further ease the pressure on crowded test labs, the AVL iCAL GNU SL combines a NOx converter checker with the AVL iCAL GDU SL Gas Divider. The SL (SlimLine) devices take up as little floor space as possible. Being about half the size of other calibration devices on the market, they can even be wall mounted. In addition, we have set new benchmarks in crucial characteristics. These include:
•    Improved performance for problematic or sticky gasses, such as NH3
•    Modern, web-based, stand-alone operation
•    Fastest purge times to reduce calibration time, gas consumption and improve results

Property Unit

Voltage supply

100, 120, 230 V AC
Gas divider and CFO principle Calibrated critical nozzles
Number of GDU cut points 15, 63, 255, 1023
Converter principle  Ozone generation by corona discharge
CFO flow rate range 10 - 10,000 ml/min (depending on model)
LFE flow rate range 1 – 16 or 1- 40 m³/min 

 

GNU SL external

The accuracy of exhaust analysis systems is highly dependent on the calibration equipment used to calibrate them. AVL has therefore developed the most precise calibration devices available on the emission market worldwide. The key benefits are: 

Reliable Operation

Achieve best reproducibility and long-term stability

Innovative Design

New internal flow design for fast, perfect span gas purge

Easy Handling

Intuitive and fully automated operation plus modern web-based stand-alone operation

Minimized Costs

Balancing high quality with cost-effectiveness

Fully Compliant

Ensuring full ISO 17025 / EPA CFR 40 part 1065 / 1066 compliance

iCAL Gas Divider SL

Designed to generate highly accurate gas mixtures, our iCAL Gas Dividers SL have the highest number of cut points (1023) which reduces the number of span gas bottles you require. They offer the best long-term stability and reproducibility thanks to the use of highly accurate sonic nozzles.

Converter Tester

The iCAL NOx converter tester reliably determines the efficiency of NOx converters used in chemiluminescence detector (CLD) analyzers. The converter tester is built into the gas divider and is based on corona discharge technology. It is optimized for a high stability of the generated NO2 and a short stabilization time.

iCAL CFO SL

To comply with regulatory demands for frequent CFO (Critical Flow Orifice) testing, we have created the iCAL CFO SL propane injection tester. It allows the introduction of a precise quantity of propane into the CVS system or into a SHED chamber. To make it even more accurate, it is temperature-stabilized at 50°C.

iCAL LFE

The AVL iCAL LFE (Laminar Flow Element) includes accurate temperature and pressure sensors and a user interface. Depending on the flow range, it enables the calibration of the flow rate of either the Critical Flow Venturis within a CVS system or the Mass-Flow Controllers in a Particulate Sampler (PSS). The sensors are connected to the flow calculation unit, which saves up to five calibration coefficients.

iCAL HBU

The iCAL HBU (Heated Bubbler Unit) is used to humidify air or test gases for the execution of quality checks on exhaust gas measurement systems. A chilled mirror hygrometer is used for a precise dew point determination. It is used to perform sample dryer and CLD quench verifications according to the EPA 40 CFR part 1065/1066 regulations.

AVL SlimLine™ Dilution Systems
AVL SlimLine™ Dilution Systems

The new benchmark for full-flow diluted emission testing is designed to take up much less space than conventional system cabinets and is built to use less energy.

SL Visual
AVL AMA SL™

The AVL AMA SL is a exhaust measurement system that is revolutionizing emission testing. It is ideally suited to both research and development applications and certification for all types of engines and fuels.

i60
AVL iGeneration SII Systems

The AVL iGENERATION Series II clears the way for intelligent and intuitive R&D and certification emission testing according to the latest worldwide emission regulations.

sesam i60
AVL SESAM i60 FT SII

The AVL SESAM i60 FT SII is a Fourier-Transform Infra-Red exhaust gas measurement system offering evaluation methods optimized for different fuels and applications.

AVL Calibration Services
Calibration Services

To ensure the correctness of measured data, is as challenging as it is critical to your product development processes. Regular calibration of your measurement instruments is essential, to secure technical credibility of your laboratory and avoid cost due to possible repetition of testing tasks.

Filter Weighing Robot
AVL Filter Weighing Management

Learn more about our Filter Weighing portfolio existing of Filter Weighing Chamber, Filter Weighing Robot and the tailored software tool AVL ParticleScale.

AVL SHED™
AVL SHED™

The AVL VT/VV-SHED (Sealed Housing for Evaporative Determination) systems constitute a state-of-the-art test system for testing evaporative emissions.

AVL CANLOAD™
AVL CANLOAD™

AVL CANLOAD is designed for the automated execution of conditioning and aging cycles of canisters containing activated carbon from the automotive sector.

AVL FUELLOAD™
AVL FUELLOAD™

AVL FUELLOAD is designed specifically for fuel conditioning and refueling procedures of vehicles or tank systems in the context of ORVR test procedures.

iGEM 2 Test Automation Solution
AVL iGEM 2™ Test Automation

AVL iGEM 2™ is our cutting-edge test automation solution for your energy and emission testing needs. It delivers high-quality data for certification and R&D testing.

Lab Management for Vehicle Process Overview
AVL Lab Management™ for Vehicle

Achieve process safety and higher efficiency with our modular and scalable Lab Management for Vehicle solution.

Process Control Modules
AVL Process Control Modules

AVL Process Control Modules constitute a powerful selection of software modules to assist you in all necessary steps involved in the testing process and result evaluation.

Insights EU7 Standards
Insights and Interpretation Into the Latest EU7 Standards
On-demand

WEBINAR - The upcoming European vehicle emission standards Euro 7 publication by the European Commission will outline testing and certification updates which will need to be addressed when developing future propulsion solutions.

Emission NFZ Key Visual final 22.11.2019
AVL Digital Tech Day: EURO 7 Regulations and Beyond
On-demand

In the coming years and decades, vehicle manufacturers and suppliers will have to face various global challenges. Reducing global warming, avoiding further greenhouse gas emission and improving local air quality will have a direct impact on relevant

GL_ITS_Images_Key Visual Emission_square
A Guide to Vehicle Emissions and Energy Testing
On-demand

In this webinar, Kurt Engeljehringer shares details of AVL’s free Emission and Energy Testing Handbook, which aims to help engineers understand and navigate this complex topic.

H2 Testing
Hydrogen ICE Testing - Challenges and Solutions
On-demand

WEBINAR - Hydrogen has the potential to be used to facilitate the shift towards zero CO2 and zero impact pollutant emissions in transport, marine, and industrial internal combustion engine (ICE) applications.

Image_OpeningCeremony
AVL Opens New Hydrogen and Fuel Cell Test Center in Graz

Greater test capacities for innovative energy and propulsion solutions

Do you have questions or want to work with us?


Our experts are happy to help.

You are currently on the AVL Global Site. Click below if you would like to switch to